Print Email PDF

QC Series Chassis Field Replacement Unit

IN THIS ARTICLE 

Outlines how to perform a chassis swap on Qumulo appliances

REQUIREMENTS

  • Qumulo QC appliance
  • Replacement chassis on site

NOTE: Shutting down the node will cause a quorum event and put the cluster in an n-1 state. Once you finish the process and power on the new chassis, another event will occur when the node rejoins quorum. 

PROCESS

  • Shut down the node
  • Unplug cabling from the back of the node
  • With help on hand, remove the original node from the rack
  • Install the new diskless chassis into the rack
  • Transfer the boot drive from the old node to the new
    • Note that on first generation 1U appliances, you will need to open the node to access the boot drive
  • Move the HDDs and SSDs from the original node to the new chassis making sure to insert the disks into the same slots.
  • Transfer the network and power cabling to the new node
  • Power on the node

NOTE: If the current IPMI settings are set statically and not via DHCP, they will need to be reapplied to each node in the cluster. Reference the IPMI Quick Reference Guide article for additional details. 

RESOLUTION

You should now be able to successfully replace a chassis on any Qumulo QC appliance 

ADDITIONAL RESOURCES

Video: HDD Field Replacement Unit

IPMI Quick Reference Guide

QQ CLI: Cluster Configuration

 

Like what you see? Share this article with your network!

Was this article helpful?
0 out of 0 found this helpful

Comments

0 comments

Please sign in to leave a comment.

Have more questions?
Open a Case
Share it, if you like it.